CONTROLLER WITH ANALOG SETTING – RE55 type
■ Destined for temperature control,
■ Input: thermocouples: J, K, S, - Resistance thermometer: PT100
■ Analog set point setting, display of measured value,
■ Control algorithms: on/off with hysteresis, PID,
■ Manual setting of PID parameters or by means of the autotuning function,
■ Control output: relay or voltage 0/5 V,
■ alarm output: relay,
■ supply: 85…253 V a.c./d.c.,
■ Overall dimensions: 96 × 96 × 65 mm.
|
 |
MICROPROCESSOR DIGITAL CONTROLLER – RE22 type
■ Destined for temperature control,
■ Input: universal (thermocouples, RTDs or standard signals),
■ Output: relay, binary 0/6 V,
■ Control algorythm: on/off, PID,
■ Manual setting of PID parameters or by means of the autotuning function,
■ Limitation of set point change setting,
■ Supply: 230 V a.c., 110 V a.c., 24 V a.c.,
■ Overall dimensions: 48 × 48 × 93 mm.
|
 |
DIGITAL CONTROLLER WITH A SIMPLE PROGRAMMER – RE23 type
■ Destined for control of temperature or other physical quantities,
■ Universal input: thermocouples, RTDs or standard signals,
■ Control according the program:
- maximally 9 segments with or without repetitions,
- segment time: 0…999 min.
- program start from the currently measured value or from the set point, after finishing
the program, control continuation of the last set point or output switching off,
■ Relay or binary 0/6 V control output for SSR control,
■ Reverse control (heating) or direct (cooling),
■ Supply: 230 V a.c., 110 V a.c., 24 V a.c.,
■ Dimensions: 48 × 48 × 93 mm. |
 |
DIGITAL CONTROLLERS – RE26 and RE18 types
■ Destined to control temperature or other physical quantities,
■ Universal input - thermocouples, resistance thermometers, standard signals,
■ Output: relay (2) (RE18), relay (2) or transistor OC type (RE 26),
■ Control algorithms: On/Off with hysteresis, PID (RE18), PID + FUZZY LOGIC (RE26) ,
■ Manual setting of PID parameters or by means of the autotuning function (RE18),
■ Kinds of control: On/Off (RE 26), On/Off, three-stage, step-by-step control (RE18),
■ Soft-start function,
■ Supply: 90...253 V a.c./d.c. or 20...40 V a.c./d.c. ,
■ Overall dimensions: 48 × 48 × 93 mm (RE26), 48 × 96 × 93 mm (RE18).
|
 |
DIGITAL CONTROLLER WITH TWO OUTPUTS – RE20 type
■ Destined for control of temperature or other physical quantities,
■ Universal input: thermocouples, RTDs or standard signals,
■ Logic input,
■ Outputs: 2 outputs: relay, continuous or binary voltage,
■ Control algorithms : on-off with hysteresis, PID,
■ Manual settings of PID parameters or by means of the autotuning function,
■ Retransmission of the measured value or the set point value,
■ RS-485 digital output, MODBUS protocol,
■ Supply: 85...253 V a.c./ d.c. or , 20...40 V a.c./d.c.
■ Dimensions: 48 × 48 × 93 mm.
|
 |
DIGITAL CONTROLLER – RE15 type
■ Destined to control temperature or other physical quantities in two measuring inputs,
■ Input: universal - thermocouples, resistance thermometers, standard signals,
■ Logic input and auxiliary analog input
■ 4 outputs: relay, transistor OC type, continuous or voltage binary,
■ Control algorithms: On/Off with hysteresis, PID, PID + FUZZY LOGIC
■ Manual setting of PID parameters or by means of the autotuning function,
■ Retransmission of measured signals or the set point,
■ Kinds of control: On/Off, two-stage, three-stage, step by step control,
■ 15 programs of the set point with 15 segments in each,
■ RS-485 digital output, MODBUS protocol,
■ Supply: 90...253 V a.c./d.c. or 20...40 V a.c./d.c.
■ Overall dimensions: 48 × 96 × 93 mm.
|
 |
DUAL-LOOP DIGITAL CONTROLLER – RE19 type
■ Destined to control temperature and other physical quantities in 2 measuring channels,
■ They are offered in three versions:
RE19P – for standard (fixed set point) control and for programming control in which
the set point changes in time acc. to the chosen program – 15 programs with 15 segments
in each program,
RE19V – for stepper motor control – 2 algorythms of step by step control, at choice,
with or without feedback,
■ 3 measuring inputs: 2 universal and a linear,
■ Arithmetical operations on input signals: addition, subtraction, multiplication,
■ 2 logic inputs,
■ 4 outputs: relay, logic 0/15V, OC, linear current and voltage,
■ Output functions: control, alarm, signaling, retransmission,
■ 2 LED displays, LCD character display (2x16),
■ 10 indexes informing about output states and working mode,
■ Kinds of set points:
- fixed, programmed: 15 programs with 15 segments in each program
(in RE19P), with 15 segments in each program (in RE19P),
- external from the auxiliary output,
■ Kinds of control: On/Off, three-stage, step by step,
■ Autotuning,
■ RS-485 interface with MODBUS protocol,
■ Overall dimensions: 96 × 96 × 74 mm. |
|
DIGITAL CONTROLLER – RE60 type
■ Destined for temperature control,
■ Input: J, K, S thermocouples, Pt100 RTD,
■ Output: 2 relays and binary,
■ Control algorithm: on/off,
■ Manual set-up of PID parameters,
■ Display: LCD, 2 × 8 digits,
■ Supply: 230 V a.c., 110 V a.c., 24 V a.c.,
■ Overall dimensions: 52.5 × 90 × 64.5 mm.
|
 |
SYSTEM FOR INJECTION MOULDS WITH HEATED CHANNELS – SR11 type
■ The SR11 system is destined for the temperature control in injection moulds
with heated channels and for other systems in plastics processing,
■ The Fuzzy Logic algorythm ensures a high accuracy of the temperature control
and optimal energy consumption,
■ The soft start function and leakage current supervision ensure the working life
extension of heaters and the work safety of the system user,
■ 1…8 control zones (the system is composed of BR11 controllers
and a set of connecting cables),
■ During the machine operation break, a decreased temperature is maintained,
what enables a fast start of the system,
■ Detection and damage signalling:
- exceeding of the admissible value of the heater leakage current,
- damage of the load circuit,
- short-circuiting, break or inverse polarization in the circuit of the sensor,
■ Output current: 0…15A
■ RS-485 digital output with MODBUS protocol and a software for monitoring
and archiving the process. |
|